Comparison

ASA FDM Filament vs PEEK

A side-by-side comparison of Acrylonitrile Styrene Acrylate Filament for FDM and Polyether Ether Ketone.

Physical

Density
1.07 g/cm³
1.32 g/cm³
Water Absorption (24h)
0.1-0.3 %
0.15 %
Transparency
Opaque
Opaque (amber)
Shrinkage
Moderate (0.4-0.7%)
1.1 – 1.4 %

Mechanical

Young's Modulus
2.5-3.0 GPa
3.6 GPa
Tensile Strength
45-55 MPa
100 MPa
Elongation at Break
4-7 %
50 %
Impact Strength (Izod)
3-6 kJ/m²
55 J/m
Flexural Strength
170 MPa

Thermal

Glass Transition Temperature
90-100 °C
143 °C
Melting Point
230-250 °C
343 °C
Continuous Service Temperature
70-80 °C
260 °C
Heat Deflection Temperature
80-90 °C @ 0.45 MPa
160 °C

Electrical

Dielectric Constant
3.0-3.2
3.2
Volume Resistivity
10¹³-10¹⁵ Ω·cm
10¹⁶ Ω·cm
Dielectric Strength
18-25 MV/m

Chemical resistance

Acids
Good resistance to dilute acids
Excellent
Bases
Moderate resistance to weak bases
Excellent
Solvents
Attacked by ketones, esters, chlorinated hydrocarbons
Excellent
UV Resistance
Excellent
Fair
Hydrolysis (steam)
Excellent

Sustainability

Recyclability
Recyclable (ABS stream, though less common)
Recyclable (specialty)
Recycling Code
7 (Other)
7
Carbon Footprint
Moderate to High
~30 kg CO₂e / kg